A survey of output intensity and potential for depth of cure among light-curing units in clinical use.

R Pilo1, D Oelgiesser, H S Cardash.   

Abstract

OBJECTIVES: The light intensity of curing lights used in private dental offices was measured using commercial curing and heat radiometers and related to uniformity of cure depth of standardized composite specimens.
METHODS: The intensity of 130 curing light from 107 dental offices was measured with curing and heat radiometers. Due to analogue readings, results were recorded in steps of 25 mW cm-2 and assigned a category number. A total of 50 lights were randomly selected to polymerize standardized 3 mm thick composite cylinders. The composite was irradiated for 50 s according to the manufacturer's instructions. The Knoop hardness value was measured at the top and bottom surfaces and the uniformity of cure depth was calculated from the ratio of these two values.
RESULTS: Light intensity measured by the curing and heat radiometers was in the range of 25-825 and 0-325 mW cm-2, respectively. Functions of maximum likelihood estimation of the top and bottom surface hardness were 57 N/N + 1.3 and 80 N/N + 17.7, respectively (N = light intensity category number). The relationship between the logarithmic transformation of the hardness ratio and light intensity was linear (R2 = 0.84 p < 0.001).
CONCLUSION: According to the manufacturer, a curing light is considered as unsuitable for use with a reading of < 200 mW cm-2 by the curing radiometer and > 50 mW cm-2 by the heat radiometer. Applying these criteria to the present study, 46% of the lights (without repetitions) required repair or replacement. The strong correlation found between the hardness ratio and light intensity verifies the usefulness of the curing radiometer in predicting the polymerization ability of the light activation units.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10079630     DOI: 10.1016/s0300-5712(98)00052-9

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  17 in total

1.  Influence of physical assessment of different light-curing units on irradiance and composite microhardness top/bottom ratio.

Authors:  Susana Morimoto; Renata Aló Maluza Zanini; Josete Barbosa Cruz Meira; Carlos Martins Agra; Fernanda Calabró Calheiros; Denis Yudi Nagase
Journal:  Odontology       Date:  2016-01-13       Impact factor: 2.634

2.  Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units.

Authors:  Olga Polydorou; Alexandros Manolakis; Elmar Hellwig; Petra Hahn
Journal:  Clin Oral Investig       Date:  2007-10-25       Impact factor: 3.573

3.  A survey of power density of light-curing units used in private dental offices in Changchun City, China.

Authors:  Xinqing Hao; Meng Luo; Jian Wu; Song Zhu
Journal:  Lasers Med Sci       Date:  2013-05-23       Impact factor: 3.161

4.  Intra- and inter-brand accuracy of four dental radiometers.

Authors:  Richard Bengt Price; Daniel Labrie; Sonya Kazmi; John Fahey; Christopher M Felix
Journal:  Clin Oral Investig       Date:  2011-05-12       Impact factor: 3.573

5.  Different depth-related polymerization kinetics of dual-cure, bulk-fill composites.

Authors:  Rong Wang; Hang Liu; Yong Wang
Journal:  Dent Mater       Date:  2019-05-22       Impact factor: 5.304

6.  Light diffusion through composite restorations added with spherical glass mega fillers.

Authors:  M Andreasi Bassi; S Andreasi Bassi; C Andrisani; S Lico; L Baggi; D Lauritano
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

7.  Comparative Evaluation of the Depth of Cure and Degree of Conversion of Two Bulk Fill Flowable Composites.

Authors:  Ca Anand Yokesh; P Hemalatha; M Muthalagu; M Robert Justin
Journal:  J Clin Diagn Res       Date:  2017-08-01

8.  Microleakage of "Bulk-Fill" Composite Resin for Class II Restorations Pretreated With CO2 Laser in Deciduous Molars: An In Vitro Study.

Authors:  Larissa Costa Santos; Ravana Angelini Sfalcin; Eugenio José Garcia; Fátima Antônia Aparecida Zanin; Aldo Brugnera Junior; Daniela Fátima Teixeira Silva; Anna Carolina Ratto Tempestini Horliana; Kristianne Porta Santos Fernandes; Raquel Agnelli Mesquita-Ferrari; Sandra Kalil Bussadori
Journal:  J Lasers Med Sci       Date:  2019-10-01

9.  Effect of Additional Light Curing on Colour Stability of Composite Resins.

Authors:  Kubra Alan Unsal; Emel Karaman
Journal:  Int Dent J       Date:  2021-08-16       Impact factor: 2.607

10.  Conversion degrees of resin composites using different light sources.

Authors:  Bora Ozturk; Nevin Cobanoglu; Ali Rıza Cetin; Beniz Gunduz
Journal:  Eur J Dent       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.