Literature DB >> 10079623

Crack formation of all-ceramic crowns dependent on different core build-up and luting materials.

J Sindel1, R Frankenberger, N Krämer, A Petschelt.   

Abstract

OBJECTIVES: The aim of this in vitro study was to evaluate various core build-up and luting materials regarding their effect on crack formation of all-ceramic crowns.
METHODS: Fifty-six freshly extracted sound human third molars were prepared according to a standardized procedure obtaining a circular shoulder of 1.5 mm with all margins located in dentin. Sixty percent of the dentin volume were removed and restored with totally bonded build-up composite resins or resin-modified glass ionomer cements (RMGIC) or compomers. Cast IPS-Empress caps were manufactured and luted with the different materials. For each material group, the volumes of the core build-ups and of the luting cements were determined. The caps were examined for cracks after 1, 3, 6, 9 and 12 months storage in 0.9% saline solution at 37 degrees C.
RESULTS: The tested groups revealed no major differences in the percentage of the core build-ups and in the volume of the luting cements. After 12 months only the group with composite resin build-up and luting showed no crack formation. RMGIC/compomer build-up or RMGIC/compomer luting always resulted in cracking of the caps.
CONCLUSIONS: Within the limits of this study it can be concluded that the hygroscopic expansion of RMGIC/compomer materials led to failure of all-ceramic crowns, when the materials are used for both core build-up or adhesive bonding.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10079623     DOI: 10.1016/s0300-5712(98)00049-9

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  9 in total

1.  Shear bond strength of self-adhesive resins compared to resin cements with etch and rinse adhesives to enamel and dentin in vitro.

Authors:  A-K Lührs; S Guhr; H Günay; W Geurtsen
Journal:  Clin Oral Investig       Date:  2009-05-09       Impact factor: 3.573

2.  Self-adhesive resin cements: pH-neutralization, hydrophilicity, and hygroscopic expansion stress.

Authors:  Lena Roedel; Vera Bednarzig; Renan Belli; Anselm Petschelt; Ulrich Lohbauer; José Zorzin
Journal:  Clin Oral Investig       Date:  2016-09-23       Impact factor: 3.573

3.  Damage of lithium-disilicate all-ceramic restorations by an experimental self-adhesive resin cement used as core build-ups.

Authors:  G Sterzenbach; G Karajouli; R Tunjan; T Spintig; K Bitter; M Naumann
Journal:  Clin Oral Investig       Date:  2014-05-28       Impact factor: 3.573

4.  Effect of seating forces on cement-ceramic adhesion in microtensile bond tests.

Authors:  Susana María Salazar Marocho; Mutlu Ozcan; Regina Amaral; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  Clin Oral Investig       Date:  2012-01-13       Impact factor: 3.573

5.  Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns.

Authors:  Ulrich Lohbauer; Renan Belli; Marco S Cune; Ulf Schepke
Journal:  SAGE Open Med Case Rep       Date:  2017-11-22

6.  Comparative evaluation of the shear bond strength of adhesive and self-adhesive resin luting agents to three commercially available composite core build-up materials: An in vitro study.

Authors:  Prachiti M Terni; Jyoti B Nadgere; Sabita M Ram; Naisargi P Shah; Janani Mahadevan
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep

7.  The Influence of Cement Layer Thickness on the Stress State of Metal Inlay Restorations-Photoelastic Analysis.

Authors:  Grzegorz Sokolowski; Michal Krasowski; Agata Szczesio-Wlodarczyk; Bartlomiej Konieczny; Jerzy Sokolowski; Kinga Bociong
Journal:  Materials (Basel)       Date:  2021-01-28       Impact factor: 3.623

Review 8.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08

9.  Effect of composite surface treatment and aging on the bond strength between a core build-up composite and a luting agent.

Authors:  Caroline Cotes; Mayra Cardoso; Renata Marques de Melo; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2015 Jan-Feb       Impact factor: 2.698

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.