Literature DB >> 10077366

The threshold for air leak: stapled versus sutured human bronchi, and experimental study.

A El-Gamel1, G M Tsang, D C Watson.   

Abstract

BACKGROUND: Little is known about the integrity of staple-closure of the bronchus and its tolerance to normal mechanical stresses (cough, sneezing, etc.) in the immediate early post-operative period. There are few studies which tested the mechanical strength of stapled bronchial closure compared with manually closed bronchi using the threshold for fluid leak across the bronchial suture line which differs from air.
MATERIAL AND METHODS: Intact cadaveric tracheobronchial tree (n = 40) were selected, age range from 55 to 70, of which 60% were males. They were divided into two groups: group A, 20 left bronchi were closed with RLV 30 Ethicon 4.8 mm bronchial stapler; group B, 20 were closed with 4 0 Prolene simple interrupted sutures. All specimens were intubated with endotracheal tube and submerged under water before testing the immediate air leak with the standard 40 mm Hg inflation pressure. Inflation pressure was increased until air leak was detected. The stapled closures were resected and subjected to radiological examination.
RESULTS: No air leak was detected in any bronchus at 40 mmHg regardless of the closure technique. The median leakage pressure was significantly higher in the hand sutured bronchi compared to the stapled group (200 vs. 105 mmHg, respectively) and 50% (n = 10) leaked from multiple sites in the stapled group compared with leakage from one site only in group B, this difference was statistically significant P < 0.001. The radiological appearance of the staples maintained the B configuration, recommended by the manufacturer as a sign of sound application.
CONCLUSION: Hand sutured bronchi tolerated higher inflation pressure compared with the stapled ones before leaking air. Air leak at high pressure occurs in the presence of intact staples.

Entities:  

Mesh:

Year:  1999        PMID: 10077366     DOI: 10.1016/s1010-7940(98)00285-1

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  2 in total

1.  Comparison of different bronchial closure techniques following pneumonectomy in dogs.

Authors:  Hakan Salci; A Sami Bayram; Ozgur Ozyigit; Cengiz Gebitekin; O Sacit Gorgul
Journal:  J Vet Sci       Date:  2007-12       Impact factor: 1.672

2.  Favorable clinical application for segmental bronchial closure based on experiment results.

Authors:  Hiroaki Kuroda; Yusuke Sugita; Keita Nakanishi; Yuko Oya; Noriaki Sakakura; Yukinori Sakao
Journal:  J Thorac Dis       Date:  2019-06       Impact factor: 2.895

  2 in total