Maximum likelihood estimation in calibrating a stereo camera setup.

A M Muijtjens1, J M Roos, T Arts, A Hasman.   

Abstract

Motion and deformation of the cardiac wall may be measured by following the positions of implanted radiopaque markers in three dimensions, using two x-ray cameras simultaneously. Regularly, calibration of the position measurement system is obtained by registration of the images of a calibration object, containing 10-20 radiopaque markers at known positions. Unfortunately, an accidental change of the position of a camera after calibration requires complete recalibration. Alternatively, redundant information in the measured image positions of stereo pairs can be used for calibration. Thus, a separate calibration procedure can be avoided. In the current study a model is developed that describes the geometry of the camera setup by five dimensionless parameters. Maximum Likelihood (ML) estimates of these parameters were obtained in an error analysis. It is shown that the ML estimates can be found by application of a nonlinear least squares procedure. Compared to the standard unweighted least squares procedure, the ML method resulted in more accurate estimates without noticeable bias. The accuracy of the ML method was investigated in relation to the object aperture. The reconstruction problem appeared well conditioned as long as the object aperture is larger than 0.1 rad. The angle between the two viewing directions appeared to be the parameter that was most likely to cause major inaccuracies in the reconstruction of the 3-D positions of the markers. Hence, attempts to improve the robustness of the method should primarily focus on reduction of the error in this parameter.

Entities:  

Mesh:

Year:  1999        PMID: 10076990     DOI: 10.1118/1.598518

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  A system for determination of 3D vessel tree centerlines from biplane images.

Authors:  K R Hoffmann; A Sen; L Lan; K G Chua; J Esthappan; M Mazzucco
Journal:  Int J Card Imaging       Date:  2000-10

2.  Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

Authors:  Jacek Dmochowski; Kenneth R Hoffmann; Vikas Singh; Jinhui Xu; Daryl P Nazareth
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

3.  Experimental comparison of cone beam CT (CBCT) reconstruction and multi-view reconstruction (MVR) for microangiography (MA) detector system.

Authors:  Vikas Patel; Andrew T Kuhls; Peter B Noël; Alan Walczak; Ciprian N Ionita; Ravishankar Chityala; Rekha Tranquebar; Hussain S Rangwala; Snehal S Kasodekar; Kenneth R Hoffmann; Daniel Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.