Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43. American Association of Physicists in Medicine.

E E Furhang1, L L Anderson.   

Abstract

This work was undertaken to expedite implementation of the AAPM Task Group 43 recommendations, which call for significant modifications in the way dose is calculated for interstitial sources of 192Ir, 125I, and 103Pd as well as significant changes in the dose rate constant for 125I sources. The TG43 recommendations include a new formalism for dose calculation at points defined by the radial distance, r, from the source center and the angle, theta, that such a radius makes with the source axis. For each source type, values are tabulated for the radial dose function, the anisotropy function, and the anisotropy factor. The TG43 report includes fitting functions for the radial dose function in the form of polynomials, which are poorly behaved outside the range of fitted data. No functions are offered for the anisotropy function data or the anisotropy factor data, both of which could profit from some smoothing by such functions. We have found a double exponential fit to the radial dose function that not only approximates the data adequately but also appropriately approaches zero for very large distances. The anisotropy function is conveniently fit with a form of type 1 - f(r,theta)cos(theta)e(cr), which is exactly 1 at theta=90 degrees and approaches 1 for large r (for c<0), where f(r,theta) is a selected polynomial in the two variables. The form chosen for the anisotropy factor was 1 - (a+br)e(cr), which appropriately approaches 1 for large r (and c<0). Functional fits of these types are expected to facilitate implementation of TG43 recommendations, in that they may be either incorporated into dose algorithms or used to generate lookup tables of either the x, y or the r, theta format.

Mesh:

Year:  1999        PMID: 10076967     DOI: 10.1118/1.598497

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Dosimetric characterization of the GammaClip™ 169Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection.

Authors:  Blake Currier; John J Munro; David C Medich
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

2.  125I inhibited the NSCLC both in vivo and in vitro.

Authors:  Weiliang Yan; Xiaodong Huo; Huixing Wang; Bin Huo; Yongtao Guo; Hua Dong; Guangjun Zheng; Junjie Wang; Shude Chai; Haitao Wang; Zuncheng Zhang
Journal:  Int J Clin Exp Pathol       Date:  2018-03-01

3.  Continuous Low-dose-rate Irradiation of Iodine-125 Seeds Inhibiting Perineural Invasion in Pancreatic Cancer.

Authors:  Zheng Lu; Teng-Hui Dong; Pei-Ren Si; Wei Shen; Yi-Liang Bi; Min Min; Xin Chen; Yan Liu
Journal:  Chin Med J (Engl)       Date:  2016-10-20       Impact factor: 2.628

4.  Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.

Authors:  Minh-Tri Ho Than; John J Munro Iii; David C Medich
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

5.  Providing a fast conversion of total dose to biological effective dose (BED) for hybrid seed brachytherapy.

Authors:  Jakub Pritz; Kenneth M Forster; Amarjit S Saini; Matthew C Biagioli; Geoffrey G Zhang
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.