Literature DB >> 10076948

A comparative study of two cerclage systems.

J Carls1, D Kohn, S Rössig.   

Abstract

Intraoperative femoral fracture is a well recognized technical complication of cementless total hip arthroplasty (THA). The aim of this study was to establish an in vitro model for initiation of fractures of the femur in cementless THA and to assess the effect of fracture fixation by cerclage wiring. An in vitro comparison of two methods of cerclage fixation was performed using steel wire (Protasul) versus multifilament Vitallium alloy cable. Ten fresh human femur specimens were studied. Longitudinal fractures were created on a material testing machine. The force to create a longitudinal fracture in the femur was 1915 N to 9288 N (median 6531 N). This force corresponds 3 to 15 times (median 11 times) the body weight. The femoral cortex was fractured in 5 cases ventrally, in 6 cases medially and in 1 case laterally. After monofile cerclage wire application, the force required to press the prosthesis 5 mm deeper into the medullary canal was 0.3-2.7 times body weight. After Vitallium alloy cable application in other specimens, the force was 1.3-2.7 times body weight. The difference was not statistically significant. After monofile cerclage wire application, a force of 1.8-8.1 times body weight was necessary to press the prosthesis 30 mm deeper into the medullary canal. After polyfile Vitallium alloy cable application in other specimens, the force was 7.7-12 times body weight. The difference was statistically significant (U-test, alpha < 0.025).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10076948     DOI: 10.1007/s004020050357

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  4 in total

1.  [The biomechanics of screws, cerclage wire and cerclage cable].

Authors:  C Schröder; M Woiczinski; S Utzschneider; M Kraxenberger; P Weber; V Jansson
Journal:  Orthopade       Date:  2013-05       Impact factor: 1.087

2.  Biomechanical performance of different cable and wire cerclage configurations.

Authors:  Mark Lenz; Stephan Marcel Perren; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Boyko Gueorguiev; Markus Windolf
Journal:  Int Orthop       Date:  2012-11-10       Impact factor: 3.075

3.  Cerclage Wiring as an Adjunct for the Treatment of Femur Fractures: Series of 11 Cases.

Authors:  Sanjay Agarwala; Aditya Menon; Sameer Chaudhari
Journal:  J Orthop Case Rep       Date:  2017 Jul-Aug

4.  Results of titanium locking plate and stainless steel cerclage wire combination in femoral fractures.

Authors:  Bilal Farouk El-Zayat; Steffen Ruchholtz; Turgay Efe; Jürgen Paletta; Dimitri Kreslo; Ralph Zettl
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.