Transcutaneous monitoring of carbon dioxide tension after cardiothoracic surgery in infants and children.

J D Tobias1, W R Wilson, D J Meyer.   

Abstract

UNLABELLED: In this prospective investigation, we evaluated the efficacy and accuracy of transcutaneous monitoring of CO2 (TC-CO2) in infants and children after cardiothoracic surgery. Cardiothoracic surgery patients whose ETCO2 and arterial CO2 values did not correlate (gradient > or = 5 mm Hg) during the first postoperative hour underwent placement of the TC electrode (30 of 33 patients). If the TC-CO2 to arterial difference was > or = 5 mm Hg, the TC-CO2 electrode was recalibrated and reapplied on another site. If the discrepancy was still > or =5 mm Hg, the case was considered a clinical failure and no further data were collected (3 of 30 patients). If the arterial to TC gradient was <5 mm Hg, the patient was included in the data collection (27 of 30 patients). One to five sample sets (TC and arterial CO2) were collected from these patients. Statistical analysis included linear regression analysis and Bland-Altman analysis. The cohort for the study included 27 patients ranging in age from 2 days to 9 yr and in weight from 3.2 to 25 kg. A total of 101 sample sets were analyzed. The mean +/- SD absolute difference between the TC-CO2 and arterial CO2 was 1.7 +/- 1.4 mm Hg (range 0-9 mm Hg). The TC-CO2 to arterial CO2 difference was 0-2 mm Hg in 82 of 101 values (81%), 35 mm Hg in 18 of 101 values (18%), and >6 mm Hg in 1 of 101 values (1%). Linear regression analysis revealed a slope of 0.90, an r value of 0.9410, and an r2 value of 0.8854 (P < 0.0001). Bland-Altman analysis revealed a bias of 0.58 mm Hg with a precision of +/- 2.1 mm Hg when comparing the TC-CO2 with the arterial CO2. IMPLICATIONS: We conclude that, with certain caveats in mind, including the need to correlate the transcutaneous CO2 with an initial arterial CO2 value, transcutaneous CO2 monitoring can be used to estimate arterial CO2 in most neonates and children after cardiothoracic surgery.

Entities:  

Mesh:

Year:  1999        PMID: 10072000     DOI: 10.1097/00000539-199903000-00012

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

Review 1.  Are carbon dioxide detectors useful in neonates?

Authors:  E J Molloy; K Deakins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

2.  An evaluation of acid-base changes following aortic cross-clamping using transcutaneous carbon dioxide monitoring.

Authors:  J D Tobias; P Russo; J Russo
Journal:  Pediatr Cardiol       Date:  2006 Sep-Oct       Impact factor: 1.655

3.  Transcutaneous CO2 Pressure Monitoring Increases Salvage Rates after Free Tissue Transplantation for Extremity Reconstruction.

Authors:  Takahiko Nakano; Toshiya Kudo; Yoshitomo Sano; Hiroaki Minehara; Masao Suzuki; Kohei Aoki; Takashi Matsushita
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-08-19

4.  Performance of capnometry in non-intubated infants in the pediatric intensive care unit.

Authors:  Bria M Coates; Robin Chaize; Denise M Goodman; Ranna A Rozenfeld
Journal:  BMC Pediatr       Date:  2014-06-25       Impact factor: 2.125

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.