Literature DB >> 10071612

Factors influencing the development of vein-graft stenosis and their significance for clinical management.

M M Idu1, J Buth, W C Hop, P Cuypers, E D van de Pavoordt, J M Tordoir.   

Abstract

OBJECTIVES: To assess the influence of clinical and graft factors on the development of stenotic lesions. In addition the implications of any significant correlation for duplex surveillance schedules or surgical bypass techniques was examined. PATIENTS AND METHODS: In a prospective three centre study, preoperative and peroperative data on 300 infrainguinal autologous vein grafts was analysed. All grafts were monitored by a strict duplex surveillance program and all received an angiogram in the first postoperative year. A revision was only performed if there was evidence of a stenosis of 70% diameter reduction or greater on the angiogram.
RESULTS: The minimum graft diameter was the only factor correlated significantly with the development of a significant graft stenosis (PSV-ratio > or = 2.5) during follow-up (p = 0.002). Factors that correlated with the development of event-causing graft stenosis, associated with revision or occlusion, were minimal graft diameter (p = 0.001), the use of a venovenous anastomosis (p = 0.005) and length of the graft (p = 0.025). Multivariate regression analysis revealed that the minimal graft diameter was the only independent factor that significantly correlated with an event-causing graft stenosis (p = 0.009). The stenosis-free rates for grafts with a minimal diameter < 3.5 mm, between 3.5-4.5 and > or = 4.5 mm were 40%, 58% and 75%, respectively (p = < 0.05). Composite vein and arm-vein grafts with minimal diameters > or = 3.5 mm were compared with grafts which consisted of a single uninterrupted greater saphenous vein with a minimal diameter of < 3.5 mm. One-year secondary patency rates in these categories were of 94% and 76%, respectively (p = 0.03).
CONCLUSIONS: A minimal graft diameter < 3.5 mm was the only factor that significantly correlated with the development of a graft-stenosis. However, veins with larger diameters may still develop stenotic lesions. Composite vein and arm-vein grafts should be used rather than uninterrupted small caliber saphenous veins.

Entities:  

Mesh:

Year:  1999        PMID: 10071612     DOI: 10.1053/ejvs.1998.0676

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  7 in total

1.  Perioperative use of eicosapentaenoic acid and patency of infrainguinal vein bypass: A retrospective chart review.

Authors:  Shinsuke Mii; Terutoshi Yamaoka; Daihiko Eguchi; Jin Okazaki; Kiyoshi Tanaka
Journal:  Curr Ther Res Clin Exp       Date:  2007-05

2.  Low levels of a natural IgM antibody are associated with vein graft stenosis and failure.

Authors:  Michael Sobel; Katherine I Moreno; Mayumi Yagi; Ted R Kohler; Gale L Tang; Alexander W Clowes; Xiao-Hua A Zhou; Evercita Eugenio
Journal:  J Vasc Surg       Date:  2013-07-13       Impact factor: 4.268

3.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

Review 4.  Adaptive changes in autogenous vein grafts for arterial reconstruction: clinical implications.

Authors:  Christopher D Owens
Journal:  J Vasc Surg       Date:  2009-10-17       Impact factor: 4.268

5.  Anti-phosphorylcholine IgM, an Anti-inflammatory Mediator, Predicts Peripheral Vein Graft Failure: A Prospective Observational Study.

Authors:  Michael Sobel; Mayumi Yagi; Katherine Moreno; Ted R Kohler; Gale L Tang; Errol S Wijelath; Julieann Marshall; Richard D Kenagy
Journal:  Eur J Vasc Endovasc Surg       Date:  2018-10-19       Impact factor: 7.069

Review 6.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

7.  A biodegradable synthetic graft for small arteries matches the performance of autologous vein in rat carotid arteries.

Authors:  Kee-Won Lee; Piyusha S Gade; Liwei Dong; Zhaoxiang Zhang; Ali Mubin Aral; Jin Gao; Xiaochu Ding; Chelsea E T Stowell; Muhammad Umer Nisar; Kang Kim; Dieter P Reinhardt; Mario G Solari; Vijay S Gorantla; Anne M Robertson; Yadong Wang
Journal:  Biomaterials       Date:  2018-07-26       Impact factor: 12.479