Comparison of four magnetic resonance methods for mapping small temperature changes.

W Wlodarczyk1, M Hentschel, P Wust, R Noeske, N Hosten, H Rinneberg, R Felix.   

Abstract

Non-invasive detection of small temperature changes (< 1 degree C) is pivotal to the further advance of regional hyperthermia as a treatment modality for deep-seated tumours. Magnetic resonance (MR) thermography methods are considered to be a promising approach. Four methods exploiting temperature-dependent parameters were evaluated in phantom experiments. The investigated temperature indicators were spin-lattice relaxation time T1, diffusion coefficient D, shift of water proton resonance frequency (water PRF) and resonance frequency shift of the methoxy group of the praseodymium complex (Pr probe). The respective pulse sequences employed to detect temperature-dependent signal changes were the multiple readout single inversion recovery (T One by Multiple Read Out Pulses; TOMROP), the pulsed gradient spin echo (PGSE), the fast low-angle shot (FLASH) with phase difference reconstruction, and the classical chemical shift imaging (CSI). Applying these sequences, experiments were performed in two separate and consecutive steps. In the first step, calibration curves were recorded for all four methods. In the second step, applying these calibration data, maps of temperature changes were generated and verified. With the equal total acquisition time of approximately 4 min for all four methods, the uncertainties of temperature changes derived from the calibration curves were less than 1 degree C (Pr probe 0.11 degrees C, water PRF 0.22 degrees C, D 0.48 degrees C and T1 0.93 degrees C). The corresponding maps of temperature changes exhibited slightly higher errors but still in the range or less than 1 degree C (0.97 degrees C, 0.41 degrees C, 0.70 degrees C, 1.06 degrees C respectively). The calibration results indicate the Pr probe method to be most sensitive and accurate. However, this advantage could only be partially transferred to the thermographic maps because of the coarse 16 x 16 matrix of the classical CSI sequence. Therefore, at present the water PRF method appears to be most suitable for MR monitoring of small temperature changes during hyperthermia treatment.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10070804     DOI: 10.1088/0031-9155/44/2/022

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  MR monitoring of tumour thermal therapy.

Authors:  D Germain; P Chevallier; A Laurent; H Saint-Jalmes
Journal:  MAGMA       Date:  2001-08       Impact factor: 2.310

2.  Radiofrequency heating at 9.4T: in vivo temperature measurement results in swine.

Authors:  Devashish Shrivastava; Timothy Hanson; Robert Schlentz; William Gallaghar; Carl Snyder; Lance Delabarre; Surya Prakash; Paul Iaizzo; J Thomas Vaughan
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

3.  Limits of a localized magnetic resonance spectroscopy assay for ex vivo myocardial triacylglycerol.

Authors:  Robert D O'Connor; Robert J Gropler; Linda Peterson; Jean Schaffer; Joseph J H Ackerman
Journal:  J Pharm Biomed Anal       Date:  2007-09-01       Impact factor: 3.935

Review 4.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

5.  [MRI for monitoring of high intensity focused ultrasound: current developments].

Authors:  C G Trumm; R Stahl; M Peller; D-A Clevert; A Huber; M F Reiser; M Matzko
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

6.  Temperature dependence of postmortem MR quantification for soft tissue discrimination.

Authors:  Wolf-Dieter Zech; Nicole Schwendener; Anders Persson; Marcel J Warntjes; Christian Jackowski
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

7.  Postmortem quantitative 1.5-T MRI for the differentiation and characterization of serous fluids, blood, CSF, and putrefied CSF.

Authors:  Wolf-Dieter Zech; Nicole Schwendener; Anders Persson; Marcel J Warntjes; Fabiano Riva; Frederick Schuster; Christian Jackowski
Journal:  Int J Legal Med       Date:  2015-07-11       Impact factor: 2.686

8.  Evaluation of MR thermometry with proton resonance frequency method at 7T.

Authors:  Ping Wang
Journal:  Quant Imaging Med Surg       Date:  2017-04

9.  Focused ultrasound modulates region-specific brain activity.

Authors:  Seung-Schik Yoo; Alexander Bystritsky; Jong-Hwan Lee; Yongzhi Zhang; Krisztina Fischer; Byoung-Kyong Min; Nathan J McDannold; Alvaro Pascual-Leone; Ferenc A Jolesz
Journal:  Neuroimage       Date:  2011-02-24       Impact factor: 6.556

10.  MR thermometry near metallic devices using multispectral imaging.

Authors:  Hans Weber; Valentina Taviani; Daehyun Yoon; Pejman Ghanouni; Kim Butts Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2016-03-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.