Literature DB >> 10070518

Comparison of the results of primary and secondary implantation of flexible open-loop anterior chamber intraocular lens.

H S Bayramlar1, I F Hepsen, O Cekiç, A Gündüz.   

Abstract

PURPOSE: To assess and compare the results of primary and secondary implantation of flexible open-loop anterior chamber intraocular lenses (AC-IOLs).
METHODS: A series of 57 eyes of 56 patients with flexible AC-IOLs were reviewed in two groups. In group I (n = 35) an AC-IOL was implanted primarily, because of posterior capsule problems during extracapsular cataract extraction (ECCE), and in group II (n = 22) secondarily after intracapsular cataract extraction (ICCE). Follow-up was from 12 to 38 months.
RESULTS: Mean post-operative best-corrected visual acuity in group I was significantly lower (20/37.38) than that of group II (20/29.20) (p = 0.044). Best corrected visual acuity of 20/40 or better was achieved in 19 of 29 eyes (65%) in group I, and in 16 of 21 eyes (76%) in group II. The difference was not statistically significant (p > 0.05). In group II 18 eyes (86%) maintained or improved visual acuity. In group I, 17 eyes (49%) had a total of 22 complications, while 7 eyes (32%) had 9 complications in group II (p > 0.05).
CONCLUSIONS: Flexible open-loop AC-IOLs are suitable for both primary and secondary implantation to correct aphakia. Secondary implantation of flexible open-loop AC-IOLs after ICCE seems to have a more favourable visual outcome and a lower complication rate than primary implantation in complicated ECCE cases.

Entities:  

Mesh:

Year:  1998        PMID: 10070518     DOI: 10.1038/eye.1998.212

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  6 in total

1.  Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

Authors:  S Kazemi; W J Wirostko; S Sinha; W F Mieler; S B Koenig; B P Sheth
Journal:  Trans Am Ophthalmol Soc       Date:  2000

2.  Comparison of outcomes of primary and secondary implantation of scleral fixated posterior chamber intraocular lens.

Authors:  V Y W Lee; H K L Yuen; A K H Kwok
Journal:  Br J Ophthalmol       Date:  2003-12       Impact factor: 4.638

3.  Long-term safety and visual outcomes of transscleral sutured posterior chamber IOLs and penetrating keratoplasty combined with transscleral sutured posterior chamber IOLs.

Authors:  Jennifer Marie Nottage; Vikram Bhasin; Verinder S Nirankari
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

4.  Aphakia correction with retropupillary fixated iris-claw lens (Artisan) - long-term results.

Authors:  Maurice Schallenberg; Dirk Dekowski; Angela Hahn; Thomas Laube; Klaus-Peter Steuhl; Daniel Meller
Journal:  Clin Ophthalmol       Date:  2013-12-23

5.  Secondary IOL Implantation without Capsular Support: A Laser Flare Cell Meter Study.

Authors:  Mauro Cellini; Ernesto Strobbe; Pier Giorgio Toschi; Emilio C Campos
Journal:  ISRN Ophthalmol       Date:  2012-01-02

6.  Anterior chamber fixation of a posterior chamber intraocular lens: a novel technique.

Authors:  A Sahap Kükner; Gürsoy Alagöz; Mesut Erdurmus; Didem Serin; Umit Dogan; Turgut Yilmaz
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.