Literature DB >> 10070094

Aortic pressure-diameter relationship assessed by intravascular ultrasound: experimental validation in dogs.

S E Hardt1, A Just, R Bekeredjian, W Kübler, H R Kirchheim, H F Kuecherer.   

Abstract

Intravascular ultrasound (IVUS) has emerged as an important diagnostic method for evaluating vessel diameter and vessel wall motion. To evaluate the validity of IVUS in assessing changes in the pressure-diameter relationship we compared measurements of abdominal aortic diameters derived from IVUS with those simultaneously obtained at the same site using implanted sonomicrometers in five chronically instrumented conscious dogs and in seven acutely instrumented anesthetized dogs. Five hundred eighty beats were analyzed to obtain peak systolic and end-diastolic diameters and to calculate aortic compliance at different blood pressure levels induced either by an aortic pneumatic cuff or by intravenous injections of nitroglycerin or norepinephrine. IVUS agreed closely with sonomicrometer measurements at different blood pressure levels. However, IVUS slightly but significantly underestimated aortic diameters by 0.6 +/- 0.7 mm for systolic diameters (P < 0.001) and by 0.7 +/- 0.6 mm for diastolic diameters (P < 0.001) compared with the sonomicrometer measurements. We conclude that IVUS is a feasible and reliable method to measure dynamic changes in aortic dimensions and has the potential to provide ready access to assess aortic compliance in humans.

Entities:  

Mesh:

Year:  1999        PMID: 10070094     DOI: 10.1152/ajpheart.1999.276.3.H1078

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  4 in total

1.  In vivo characterization of the aortic wall stress-strain relationship.

Authors:  Asawinee Danpinid; Jianwen Luo; Jonathan Vappou; Pradit Terdtoon; Elisa E Konofagou
Journal:  Ultrasonics       Date:  2010-01-14       Impact factor: 2.890

2.  In vivo and in vitro measurements of pulmonary arterial stiffness: A brief review.

Authors:  Lian Tian; Naomi C Chesler
Journal:  Pulm Circ       Date:  2012-10       Impact factor: 3.017

3.  Ballistocardiogram: Mechanism and Potential for Unobtrusive Cardiovascular Health Monitoring.

Authors:  Chang-Sei Kim; Stephanie L Ober; M Sean McMurtry; Barry A Finegan; Omer T Inan; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2016-08-09       Impact factor: 4.379

4.  Arterial Hypertension and Unusual Ascending Aortic Dilatation in a Neonate With Acute Kidney Injury: Mechanistic Computer Modeling.

Authors:  Luis Altamirano-Diaz; Andrea D Kassay; Baran Serajelahi; Christopher W McIntyre; Guido Filler; Sanjay R Kharche
Journal:  Front Physiol       Date:  2019-11-08       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.