Literature DB >> 10067999

Meniscal movement. An in-vivo study using dynamic MRI.

V Vedi1, A Williams, S J Tennant, E Spouse, D M Hunt, W M Gedroyc.   

Abstract

We present the first study in vivo of meniscal movement in normal knees under load. Using an open MR scanner, allowing imaging in physiological positions in near to real-time, 16 young footballers were scanned moving from full extension to 90 degrees flexion in the sagittal and coronal planes. Excursion of the meniscal horns, radial displacement and meniscal height were measured. On weight-bearing, the anterior horn of the medial meniscus moves through a mean of 7.1 mm and the posterior horn through 3.9 mm, with 3.6 mm of mediolateral radial displacement. The height of the anterior horn increases by 2.6 mm and that of the posterior horn by 2.0 mm. The anterior horn of the lateral meniscus moves 9.5 mm and the posterior horn 5.6 mm, with 3.7 mm of radial displacement. The height of the anterior horn increases by 4.0 mm, and that of the posterior horn by 2.4 mm. In non-weight-bearing, the anterior horn of the medial meniscus moves 5.4 mm and the posterior horn 3.8 mm, with 3.3 mm of radial displacement. The anterior horn of the lateral meniscus moves 6.3 mm, and the posterior horn 4.0 mm, with 3.4 mm of radial displacement. The most significant differences between weight-bearing and non-weight-bearing were the movement and vertical height of the anterior horn of the lateral meniscus.

Mesh:

Year:  1999        PMID: 10067999     DOI: 10.1302/0301-620x.81b1.8928

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  85 in total

1.  Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.

Authors:  T G Tienen; P Buma; J G F Scholten; A van Kampen; R P H Veth; N Verdonschot
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-08-11       Impact factor: 4.342

2.  Meniscus root refixation technique using a modified Mason-Allen stitch.

Authors:  Dhong Won Lee; Suk Hwan Jang; Jeong Ku Ha; Jin Goo Kim; Jin Hwan Ahn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-21       Impact factor: 4.342

3.  Rehabilitation following meniscal repair.

Authors:  John T Cavanaugh; Sarah E Killian
Journal:  Curr Rev Musculoskelet Med       Date:  2012-03

4.  Width is a more important predictor in graft extrusion than length using plain radiographic sizing in lateral meniscal transplantation.

Authors:  Bum-Sik Lee; Jong-Won Chung; Jong-Min Kim; Kyung-Ah Kim; Seong-Il Bin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-19       Impact factor: 4.342

5.  Association between tears of the posterior root of the medial meniscus and far posterior femoral condyle osteoarthritis.

Authors:  Ronnie Sebro; S Sharon Ashok; Matthew Uriell
Journal:  Diagn Interv Radiol       Date:  2020-07       Impact factor: 2.630

6.  Relationship between ultrastructure and biomechanical properties of the knee meniscus.

Authors:  A Gabrion; P Aimedieu; Z Laya; E Havet; P Mertl; R Grebe; M Laude
Journal:  Surg Radiol Anat       Date:  2005-11-25       Impact factor: 1.246

7.  A biomechanical study of the meniscofemoral ligaments and their contribution to contact pressure reduction in the knee.

Authors:  Hippolite O Amadi; Chinmay M Gupte; Denny T T Lie; Ian D McDermott; Andrew A Amis; Anthony M J Bull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-08-19       Impact factor: 4.342

8.  Using functional tissue engineering and bioreactors to mechanically stimulate tissue-engineered constructs.

Authors:  David L Butler; Shawn A Hunter; Kumar Chokalingam; Michael J Cordray; Jason Shearn; Natalia Juncosa-Melvin; Sanjit Nirmalanandhan; Abhishek Jain
Journal:  Tissue Eng Part A       Date:  2009-04       Impact factor: 3.845

9.  Dynamic MR imaging of a minipig's knee using a high-density multi-channel receive array and a movement device.

Authors:  Sairamesh Raghuraman; Joachim H X Schrauth; Daniel L Weber; Frank Resmer; Meike Haddad-Weber; Felix A Breuer; Ulrich Nöth; Peter M Jakob; Titus Lanz; Daniel Haddad
Journal:  MAGMA       Date:  2012-09-27       Impact factor: 2.310

10.  From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments.

Authors:  Adam C Abraham; Tammy L Haut Donahue
Journal:  Acta Biomater       Date:  2013-02-04       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.