Literature DB >> 10064121

Indirect reference limits estimated from patients' results by three mathematical procedures.

M Ferré-Masferrer1, X Fuentes-Arderiu, R Puchal-Añe.   

Abstract

Presently, only a few clinical laboratories produce their own reference values, while the great majority use reference intervals reported in the literature. An alternative to this unsatisfactory situation is to estimate indirect reference limits by means of mathematical/statistical procedures from patients' results obtained routinely in the laboratory. The procedures of Bhattacharya (A simple method of resolution of a distribution into Gaussian components. Biometrics 1967;23:115-135) Martin et al. (Reference values based on populations accessible to hospitals. In: Gräsbeck R, Alström T, editors. Reference Values in Laboratory Medicine. Chischester: Wiley, 1981:233-262) and Kairisto et al. (Generation of reference values for cardiac enzymes from hospital admission laboratory data. Eur J Clin Chem Clin Biochem 1994;32:789-796) were applied to 14 biochemical quantities. In order to verify these procedures, the indirect reference limits obtained from patients' results were validated by statistical comparison with reference limits estimated from a reference sample according to recommendations of the International Federation of Clinical Chemistry (IFCC). Calculated indirect reference limits for most quantities studied were reliable, but indirect reference limits for bilirubins and potassium ion substance concentrations, alanine aminotransferase, and aspartate aminotransferase catalytic concentrations in serum were not suitable. We conclude that indirect reference limits can be obtained from patients' results by all procedures studied when skewness and kurtosis of mixed distribution are not too large, but other factors also seem to have an influence on the reliability of these procedures.

Entities:  

Mesh:

Year:  1999        PMID: 10064121     DOI: 10.1016/s0009-8981(98)00164-8

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Prerequisites for use of common reference intervals.

Authors:  Ferruccio Ceriotti
Journal:  Clin Biochem Rev       Date:  2007-08

2.  Indirect reference intervals estimated from hospitalized population for thyrotropin and free thyroxine.

Authors:  Tamer C Inal; Mustafa Serteser; Abdurrahman Coşkun; Aysel Ozpinar; Ibrahim Unsal
Journal:  Croat Med J       Date:  2010-04       Impact factor: 1.351

3.  Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females.

Authors:  Ingvar Ryden; Lars Lind; Anders Larsson
Journal:  Ups J Med Sci       Date:  2012-02-03       Impact factor: 2.384

4.  Reference intervals established using indirect method for serum ferritin assayed on Abbott Architect i2000SR analyzer in Chinese adults.

Authors:  Qing-Ping Wang; Lin-Ying Guo; Zhi-Yong Lu; Jian-Wen Gu
Journal:  J Clin Lab Anal       Date:  2019-11-01       Impact factor: 2.352

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.