Literature DB >> 10052658

Effects of repetitive dynamic contractions upon electromechanical delay.

D A Gabriel1, J P Boucher.   

Abstract

The effect of repeated maximal effort isotonic contractions on electromechanical delay was studied. Over 4 days, 17 male subjects performed 400 rapid elbow flexion trials. The kinematics and surface electromyographic (EMG) activity of the biceps brachii of these subjects were recorded. The period from the onset of the EMG until the beginning of movement was defined as the electromechanical delay. The period from the beginning of movement until the end of the EMG was defined as the second component of the contraction. Over the 4 day period there was an increase in the speed of limb movement. The mean power frequency and the duration of the EMG during the electromechanical delay did not change, while the root-mean-square amplitude increased. The duration of the EMG during the second component of the contraction remained stable. The mean power frequency and the root-mean-square amplitude of the EMG during the second component of the contraction increased with the speed of limb movement. We conclude that the faster contractions were a result of changes in motor unit recruitment during the second component of the contraction, rather than in the electromechanical delay.

Mesh:

Year:  1998        PMID: 10052658     DOI: 10.1007/s004210050470

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  8 in total

1.  Differential segmental strain during active lengthening in a large biarticular thigh muscle during running.

Authors:  Jennifer A Carr; David J Ellerby; Richard L Marsh
Journal:  J Exp Biol       Date:  2011-10-15       Impact factor: 3.312

2.  Electromechanical delay of the knee extensor muscles is not altered after harvesting the patellar tendon as a graft for ACL reconstruction: implications for sports performance.

Authors:  A D Georgoulis; S Ristanis; A Papadonikolakis; E Tsepis; U Moebius; C Moraiti; N Stergiou
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-06-21       Impact factor: 4.342

3.  Relationships between surface EMG variables and motor unit firing rates.

Authors:  Anita Christie; J Greig Inglis; Gary Kamen; David A Gabriel
Journal:  Eur J Appl Physiol       Date:  2009-06-21       Impact factor: 3.078

4.  Acute effects of passive stretching on the electromechanical delay and evoked twitch properties.

Authors:  Pablo B Costa; Eric D Ryan; Trent J Herda; Ashley A Walter; Katherine M Hoge; Joel T Cramer
Journal:  Eur J Appl Physiol       Date:  2009-09-26       Impact factor: 3.078

5.  Peroneal electromechanical delay and fatigue in patients with chronic ankle instability.

Authors:  Dimitrios A Flevas; Manfred Bernard; Stavros Ristanis; Constantina Moraiti; Anastasios D Georgoulis; Evangelos Pappas
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-11       Impact factor: 4.342

6.  Effect of laterality and fatigue in peroneal electromechanical delay.

Authors:  Dimitrios A Flevas; Evangelos Pappas; Stavros Ristanis; Giannis Giakas; Marios Vekris; Anastasios D Georgoulis
Journal:  SICOT J       Date:  2022-05-26

7.  IMU Motion Capture Method with Adaptive Tremor Attenuation in Teleoperation Robot System.

Authors:  Huijin Zhu; Xiaoling Li; Long Wang; Zhangyi Chen; Yueyang Shi; Shuai Zheng; Min Li
Journal:  Sensors (Basel)       Date:  2022-04-27       Impact factor: 3.847

8.  Neural, biomechanical, and physiological factors involved in sex-related differences in the maximal rate of isometric torque development.

Authors:  J Greig Inglis; Kyle McIntosh; David A Gabriel
Journal:  Eur J Appl Physiol       Date:  2016-11-04       Impact factor: 3.078

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.