Literature DB >> 10052384

Geometric and densitometric standardization of intraoral radiography through use of a modified XCP system.

T E Southard1, D M Wunderle, K A Southard, J R Jakobsen.   

Abstract

OBJECTIVE: The purposes of this study were to examine the density correction afforded by curve-fitting algorithms and to investigate whether the device we developed significantly improves the reliability of longitudinal alveolar process bone radiographic density measurements. STUDY
DESIGN: Stepwedges were radiographed over a range of impulse settings, and curve-fitting algorithms were fitted to sets of step images on each digitized film. Differences between the actual thicknesses of an alternate set of steps and their corresponding thickness estimates were calculated. Next, clinicians made periapical radiographs from interproximal bony sites on a dry skull using our imaging device. Differences in bone densities between corresponding regions of interest taken 1 week apart were calculated.
RESULTS: Analysis of variance and Duncan's Multiple Range test demonstrated that piecewise linear, third-degree polynomial, and fourth-degree polynomial curves provided significantly better estimates of stepwedge thickness than did sigmoid or first degree polynomial-curves (P < .05) and that the differences between repeat bone density measurements made with density correction were significantly less than those made without density correction (P < .05).
CONCLUSIONS: Piecewise linear, third-degree polynomial, and fourth-degree polynomial curve-fitting algorithms provided the best densitometric correction. The use of our imaging device increased the reliability of longitudinal bone density measurements.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10052384     DOI: 10.1016/s1079-2104(99)70281-7

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  3 in total

1.  Quantitative analysis of bone density in direct digital radiographs evaluated by means of computerized analysis of digital images.

Authors:  C Morea; G C Dominguez; A Coutinho; I Chilvarquer
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

2.  Comparison of Conventional and Standardized Bone Densitometry around Implants in Periapical Radiographs during a Three Months Period.

Authors:  Asieh Zamani Naser; Shahab Etemadi; Mansour Rismanchian; Mahnaz Sheikhi; Mohammadbagher Tavakoli
Journal:  Dent Res J (Isfahan)       Date:  2011

3.  The effects of image acquisition control of digital X-ray system on radiodensity quantification.

Authors:  Wook-Jin Seong; Hyeon-Cheol Kim; Soocheol Jeong; Youngcheul Heo; Woo-Bin Song; Mansur Ahmad
Journal:  Restor Dent Endod       Date:  2013-08-23