Literature DB >> 10048668

Post-mortem cast angiography in the diagnostics of graft complications in patients with fatal outcome following coronary artery bypass grafting (CABG).

S M Weman1, U S Salminen, A Penttilä, A Männikkö, P J Karhunen.   

Abstract

The advantages and limitations of a novel post-mortem angiographic method using solidifying silicone rubber and lead oxide as a contrast medium in detecting coronary artery graft complications on a routine basis were evaluated in a series of 223 consecutive patients with fatal outcome within 30 days following coronary artery bypass grafting (CABG). Of these patients, 166 (74.4%) were male and 57 (25.6%) female (mean age 61.9 +/- 9). Coronary grafts totalled 660 (3.0 per patient) with 517 aortic and 838 coronary anastomoses. At autopsy, the rubber cast model of the grafts and coronary arterial tree was exposed by a bend scalpel and sites of possible complications were examined. Post-mortem angiographs were re-evaluated and compared with preoperative angiographs and dissection findings. By combining the findings of angiography and heart dissection, 122 (54.7%) of the 223 patients were found to have some type of complication of the graft or the anastomosis. The diagnostic sensitivity and specificity of post-mortem angiography was 100% in assessing narrowing or twisting of the graft as well as narrowing of the aortal anastomosis, whereas these findings were revealed with difficulty by autopsy dissection only. In cases with correct x-ray projection, narrowing and occlusion of the proximal aortal and distal coronary anastomosis were also reliably revealed by angiography. In contrast, graft thrombosis was clearly overdiagnosed by angiography, leading to a lower specificity (84%) but high sensitivity (100%) in detecting this complication. Post-mortem angiography also failed to detect dissection of the wall of the graft or anastomosis. Technical problems with this angiographic method were due to too low perfusion pressure, too rapid polymerizing of the silicone rubber, leakage of contrast medium into the ventricles, or faulty x-ray projections. These results suggest that our post-mortem angiographic technique, yielding a permanent rubber-cast model of the graft and anastomosis site, improves the accuracy of diagnostics of postoperative CABG complications and eases postoperative autopsy dissection, which can now be directed to confirm suspected complications.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10048668     DOI: 10.1007/s004140050211

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  8 in total

1.  Dose dependent but non-linear effects of alcohol on the left and right ventricle.

Authors:  O A Kajander; M Kupari; P Laippala; V Savolainen; J Pajarinen; A Penttilä; P J Karhunen
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

Review 2.  Acp. Best practice no 155. Pathological investigation of deaths following surgery, anaesthesia, and medical procedures.

Authors:  R D Start; S S Cross
Journal:  J Clin Pathol       Date:  1999-09       Impact factor: 3.411

3.  Attenuation of Maladaptive Responses in Aortic Adventitial Fibroblasts through Stimuli-Triggered siRNA Release from Lipid-Polymer Nanocomplexes.

Authors:  Chad T Greco; Robert E Akins; Thomas H Epps; Millicent O Sullivan
Journal:  Adv Biosyst       Date:  2017-07-20

4.  A new way to use transit-time flow measurement for coronary artery bypass grafting.

Authors:  Lukas Stastny; Markus Kofler; Vitalijs Zujs; Elfriede Ruttmann; Julia Dumfarth; Juliane Kilo; Alexandra Brix; Simone Gasser; Adel Sakic; Thomas Schachner; Michael Grimm; Nikolaos Bonaros
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10

5.  Medico-legal autopsy in postoperative hemodynamic collapse following coronary artery bypass surgery.

Authors:  Janne P Karhunen; Pekka J Karhunen; Peter M Raivio; Eero I T Sihvo; Tiina L S Vainikka; Ulla-Stina Salminen
Journal:  Forensic Sci Med Pathol       Date:  2010-09-07       Impact factor: 2.007

6.  Mild anastomotic stenosis in patient-specific CABG model may enhance graft patency: a new hypothesis.

Authors:  Yunlong Huo; Tong Luo; Julius M Guccione; Shawn D Teague; Wenchang Tan; José A Navia; Ghassan S Kassab
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240

7.  COX-2 gene promoter polymorphism and coronary artery disease in middle-aged men: the Helsinki sudden death study.

Authors:  Kati H Huuskonen; Tarja A Kunnas; Minna M Tanner; Jussi Mikkelsson; Erkki Ilveskoski; Pekka J Karhunen; Seppo T Nikkari
Journal:  Mediators Inflamm       Date:  2008       Impact factor: 4.711

8.  Expression of sterol regulatory element-binding transcription factor (SREBF) 2 and SREBF cleavage-activating protein (SCAP) in human atheroma and the association of their allelic variants with sudden cardiac death.

Authors:  Yue-Mei Fan; Pekka J Karhunen; Mari Levula; Erkki Ilveskoski; Jussi Mikkelsson; Olli A Kajander; Otso Järvinen; Niku Oksala; Janita Thusberg; Mauno Vihinen; Juha-Pekka Salenius; Leena Kytömäki; Juhani T Soini; Reijo Laaksonen; Terho Lehtimäki
Journal:  Thromb J       Date:  2008-12-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.