Literature DB >> 10047644

A novel comparison of stentless versus stented valves in the small aortic root.

V Rao1, G T Christakis, J Sever, S E Fremes, G Bhatnagar, G Cohen, M A Borger, L Abouzahr, B S Goldman.   

Abstract

BACKGROUND: Previous studies have compared prosthetic valves on the basis of industry-labeled valve sizes. Unfortunately, the relationship between the labeled size and the true measured external or internal diameter differs between valve manufacturers. Therefore hemodynamic comparisons between prosthetic valves are inaccurate if based solely on industry-labeled valve sizes.
METHODS: We have previously demonstrated that the internal diameter of a 21-mm Carpentier-Edwards pericardial stented valve is similar to that of a 25-mm Toronto stentless porcine valve. Therefore we chose to compare postoperative hemodynamics in patients who received 19-, 21-, or 23-mm Carpentier-Edwards pericardial stented valves (inner diameter 18-22 mm, n = 69) with those in patients who received 23- or 25-mm stentless porcine valves (internal diameter 19-21 mm, n = 41).
RESULTS: Patients in the Carpentier-Edwards group were more likely to be elderly and more likely to require concomitant revascularization. Operative mortality was lower in the stentless porcine valve group (0% vs 9%, P =.06). Hospital stay and ventilation requirements were shorter in the stentless porcine valve group. Postoperative hemodynamics were similar in the two groups.
CONCLUSIONS: These data provide evidence that stentless and stented valves have similar hemodynamic profiles in the small aortic root when matched on true measured internal diameters. The clinical benefit of the stentless porcine valve may be due to patient selection or the lack of a rigid stent in the small aortic root, but it is not due to hemodynamic superiority over stented aortic valves of similar sizes.

Entities:  

Mesh:

Year:  1999        PMID: 10047644     DOI: 10.1016/s0022-5223(99)70321-1

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Long-term Mortality Predictors in Patients with Small Aortic Annulus Undergoing Aortic Valve Replacement with a 19- or 21-mm Bioprosthesis.

Authors:  Jenny Lourdes Rivas de Oliveira; Renato Tambellini Arnoni; Magaly Arrais dos Santos; Antonio Flávio Sanchez Almeida; Mário Issa; Antoninho Sanfins Arnoni; Paulo Chaccur; Luiz Carlos Bento de Souza
Journal:  Braz J Cardiovasc Surg       Date:  2016 Jul-Sep

2.  Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis.

Authors:  Edvin Prifti; Massimo Bonacchi; Fadil Ademaj; Gabriele Giunti; Giampiero Esposito; Arben Baboci; Gani Bajraktari; Altin Veshti; Aurel Demiraj; Vittorio Vanini
Journal:  J Cardiothorac Surg       Date:  2015-11-06       Impact factor: 1.637

  2 in total