Literature DB >> 10036652

Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures.

P E Haers1, H F Sailer.   

Abstract

Biodegradable self-reinforced poly-L/DL-lactide plates and screws were used for osteosynthesis in 10 consecutive cases of bimaxillary procedures with simultaneous genioplasties, without postoperative rigid intermaxillary fixation. During surgery, data were gathered concerning failure of the osteosynthesis material. Clinical examination was carried out weekly until the sixth postoperative week. Cephalometric analysis of standardized cephalograms was performed to evaluate the short-term skeletal stability pattern, which was compared with similar reports in the literature. Six weeks postoperatively, all jaws were clinically stable and there was no clinical evidence of foreign body reactions. For the whole group (n = 10), the mean maxillary advancement at point A was 2.9 mm with a mean postoperative relapse of 0.0 mm. The mean advancement at point B was 2.8 mm with a mean additional advancement postoperatively of 1.1 mm. The mean vertical surgical displacement at point A was directed inferiorly with a value of 1.8 mm and a relapse of -0.4 mm. At point B the corresponding values were 1.9 mm and -0.4 mm. In the Angle Class III group (n = 4), the mean advancement at A was 5.9 mm with an additional postoperative advancement of 0.3 mm. In the Angle Class II group (n = 6), mean advancement at point B was 4.0 mm, with an additional postoperative advancement of 1.1 mm. In the group with short face deformity (n = 3), the mean inferior movement in ANS was 6.6 mm with a relapse of -0.2 mm. At menton the vertical surgical movement was 13.0 mm with a relapse of -0.2 mm. None of the plates, which were bent at room temperature, broke. The screw heads broke or had an insufficient fit in the bone in 12 of 305 (3.9%) screws. It can be concluded that the tested system of biodegradable self-reinforced poly-L/DL-lactide screws and plates has a small material-related failure rate, and that their application in orthognathic surgery leads to a predictable short-term skeletal stability pattern which is comparable to the 'gold standard' of titanium plates and screws.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10036652     DOI: 10.1016/s1010-5182(98)80069-3

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  9 in total

1.  [Retrospective view of the development of malocclusion surgery and prospects].

Authors:  E W Steinhäuser
Journal:  Mund Kiefer Gesichtschir       Date:  2003-11-07

2.  Choice of internal rigid fixation materials in the treatment of facial fractures.

Authors:  Mirko S Gilardino; Elliot Chen; Scott P Bartlett
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2009-03

3.  Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients.

Authors:  T A Turvey; W P Proffit; C Phillips
Journal:  Int J Oral Maxillofac Surg       Date:  2010-12-24       Impact factor: 2.789

4.  Are bioresorbable polylactate devices comparable to titanium devices for stabilizing Le Fort I advancement?

Authors:  G H Blakey; E Rossouw; T A Turvey; C Phillips; W R Proffit; R P White
Journal:  Int J Oral Maxillofac Surg       Date:  2013-11-20       Impact factor: 2.789

5.  Biomaterials for craniofacial reconstruction.

Authors:  Andreas Neumann; Kevin Kevenhoerster
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

Review 6.  Bioabsorbable osteofixation for orthognathic surgery.

Authors:  Young-Wook Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-02-19

7.  Comparative study on long-term stability in mandibular sagittal split ramus osteotomy: hydroxyapatite/poly-l-lactide mesh versus titanium miniplate.

Authors:  Young-Wook Park; Hyun-Sik Kang; Jang-Ha Lee
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-03-01

Review 8.  A Narrative Review of u-HA/PLLA, a Bioactive Resorbable Reconstruction Material: Applications in Oral and Maxillofacial Surgery.

Authors:  Huy Xuan Ngo; Yunpeng Bai; Jingjing Sha; Shinji Ishizuka; Erina Toda; Rie Osako; Akira Kato; Reon Morioka; Mrunalini Ramanathan; Hiroto Tatsumi; Tatsuo Okui; Takahiro Kanno
Journal:  Materials (Basel)       Date:  2021-12-26       Impact factor: 3.623

Review 9.  Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances.

Authors:  Barzi Gareb; Nico B Van Bakelen; Arjan Vissink; Ruud R M Bos; Baucke Van Minnen
Journal:  Polymers (Basel)       Date:  2022-07-07       Impact factor: 4.967

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.