Literature DB >> 10030419

Filtered versus unfiltered technetium sulfur colloid in lymphatic mapping: a significant variable in a pig model.

L Tafra1, A N Chua, P C Ng, D Aycock, M Swanson, D Lannin.   

Abstract

BACKGROUND: Lymphatic mapping with sentinel node biopsy is becoming a standard diagnostic test for melanoma and is being extensively investigated for use with other soft tissue tumors. Both filtered and unfiltered technetium sulfur colloid (Tc 99) have been used for preoperative lymphoscintigraphy, as well as intraoperative lymphatic mapping, and it is not clear if one is preferable over the other. The purpose of this study was to compare these two preparations to determine whether the form of Tc 99 used affects the results of lymphatic mapping.
METHODS: Mock skin sites were placed on each extremity of 12 domestic pigs totaling 48 skin sites. Twenty-four of the lesions were injected with unfiltered Tc 99; the remaining 24 were injected with Tc 99 passed over a 0.2-microm filter. Both preparations of Tc 99 were mixed with 1 mL of isosulfan blue before injection. Sentinel node dissection was performed using a gamma probe, with counts recorded over a 10-second period and timed to begin 5 minutes after injection.
RESULTS: Sentinel nodes were identified in all 48 lymph node basins draining the mock sites and characterized as hot (10x background), blue, or both. Significantly more sentinel nodes were found in the filtered (105 total, X = 4.4/basin), than in the unfiltered group (total 53, X = 2.2/basin, P <.0001). The filtered group had both a higher number of nodes that were hot (35 vs. 6) and more nodes that were hot and blue (69 vs. 43). In addition, hot secondary level lymph nodes (iliac and deep cervical) were found in 11 of 24 of the basins (46%) in the filtered group compared to 1 of 24 (4%) in the unfiltered group (P <.003). There was no significant difference in injection site or residual basin counts between the two groups, but in vivo counts over the sentinel node sites were significantly lower in the unfiltered group (X = 2670+/-1829 vs. X = 6027+/-4333; P = .003).
CONCLUSION: Use of filtered Tc 99 results in more sentinel nodes (both hot/blue and hot non-blue) and a higher proportion of secondary lymph nodes. These findings indicate that the Tc 99 preparation used is a significant variable in the results of lymphatic mapping. It is critical that future clinical studies document which preparation of Tc 99 was used. Only large clinical trials will be able to determine whether the additional nodes found with filtered Tc 99 increase the sensitivity of the technique or merely increase the number of nodes that must be removed unnecessarily.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10030419     DOI: 10.1007/s10434-999-0083-7

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  4 in total

Review 1.  The inextricable axis of targeted diagnostic imaging and therapy: An immunological natural history approach.

Authors:  Frederick O Cope; Bonnie Abbruzzese; James Sanders; Wendy Metz; Kristyn Sturms; David Ralph; Michael Blue; Jane Zhang; Paige Bracci; Wiam Bshara; Spencer Behr; Toby Maurer; Kenneth Williams; Joshua Walker; Allison Beverly; Brooke Blay; Anirudh Damughatla; Mark Larsen; Courtney Mountain; Erin Neylon; Kaeli Parcel; Kapil Raghuraman; Kevin Ricks; Lucas Rose; Akhilesh Sivakumar; Nicholas Streck; Bryan Wang; Christopher Wasco; Larry S Schlesinger; Abul Azad; Murugesan V S Rajaram; Wael Jarjour; Nicholas Young; Thomas Rosol; Amifred Williams; Michael McGrath
Journal:  Nucl Med Biol       Date:  2015-12-03       Impact factor: 2.408

2.  Multicenter trial of sentinel node biopsy for breast cancer using both technetium sulfur colloid and isosulfan blue dye.

Authors:  L Tafra; D R Lannin; M S Swanson; K M Verbanac; A N Chua; P C Ng; M S Edwards; B E Halliday; C A Henry; L M Sommers; C M Carman; M R Molin; J E Yurko; R R Perry; R Williams
Journal:  Ann Surg       Date:  2001-01       Impact factor: 12.969

3.  How many sentinel lymph nodes are enough during sentinel lymph node dissection for breast cancer?

Authors:  Min Yi; Funda Meric-Bernstam; Merrick I Ross; Jeri S Akins; Rosa F Hwang; Anthony Lucci; Henry M Kuerer; Gildy V Babiera; Michael Z Gilcrease; Kelly K Hunt
Journal:  Cancer       Date:  2008-07-01       Impact factor: 6.860

4.  Combined analysis of phase III trials evaluating [⁹⁹mTc]tilmanocept and vital blue dye for identification of sentinel lymph nodes in clinically node-negative cutaneous melanoma.

Authors:  Vernon K Sondak; Dennis W King; Jonathan S Zager; Schlomo Schneebaum; Julian Kim; Stanley P L Leong; Mark B Faries; Bruce J Averbook; Steve R Martinez; Christopher A Puleo; Jane L Messina; Lori Christman; Anne M Wallace
Journal:  Ann Surg Oncol       Date:  2012-10-03       Impact factor: 5.344

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.