A potentiometric urea-sensitive biosensor using a NH4(+)-sensitive disposable electrode in double matrix membrane (DMM) technology as transducer is described. The ion-sensitive polymer matrix membrane was formed in the presence of an additional electrochemical inert filter paper matrix to improve the reproducibility in sensor production. The electrodes were prepared from one-side silver-coated filter paper, which is encapsulated for insulation by a heat-sealing film. A defined volume of the NH4(+)-sensitive polymer matrix membrane cocktail was deposited on this filter paper. To obtain the urea-biosensor a layer of urease was cast onto the ion-sensitive membrane. Poly (carbamoylsulfonate) hydrogel, produced from a hydrophilic polyurethane prepolymer blocked with bisulfite, served as immobilisation material. The disposable urea sensitive electrode was combined with a disposable Ag/AgCl reference electrode to obtain the disposable urea biosensor. The sensor responded rapidly and in a stable manner to changes in urea concentrations between 7.2 x 10(-5) and 2.1 x 10(-2)mol/l. The detection limit was 2 x 10(-5) mol/l urea and the slope in the linear range 52 mV/decade. By taking into consideration the influence of the interfering K(+)- and Na(+)-ions the sensor can be used for the determination of urea in human blood and serum samples (diluted or undiluted). A good correlation was found with the data obtained by the spectrophotometric routine method.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10028647     DOI: 10.1016/s0956-5663(98)00103-1

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Use of Water Soluble and Phosphorescent MPA-capped CdTe Quantum Dots for the Detection of Urea.

Authors:  Tülay Oymak; Nusret Ertaş; Uğur Tamer
Journal:  Turk J Pharm Sci       Date:  2018-04-02

2.  Voltammetric Detection of Urea on an Ag-Modified Zeolite-Expanded Graphite-Epoxy Composite Electrode.

Authors:  Florica Manea; Aniela Pop; Ciprian Radovan; Plamen Malchev; Adriana Bebeselea; Georgeta Burtica; Stephen Picken; Joop Schoonman
Journal:  Sensors (Basel)       Date:  2008-09-22       Impact factor: 3.576

Review 3.  Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.

Authors:  Antonio Tricoli; Giovanni Neri
Journal:  Sensors (Basel)       Date:  2018-03-22       Impact factor: 3.576

4.  Fabrication of a Urea Biosensor for Real-Time Dynamic Fluid Measurement.

Authors:  Kyunghee Kim; Jeongeun Lee; Bo Mi Moon; Ye Been Seo; Chan Hum Park; Min Park; Gun Yong Sung
Journal:  Sensors (Basel)       Date:  2018-08-09       Impact factor: 3.576

5.  Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite.

Authors:  Gautam Das; Hyon Hee Yoon
Journal:  Int J Nanomedicine       Date:  2015-08-25

6.  A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations.

Authors:  Wei-Jhe Ma; Ching-Hsing Luo; Jiun-Ling Lin; Sin-Houng Chou; Ping-Hung Chen; Mei-Jywan Syu; Shin-Hung Kuo; Shin-Chi Lai
Journal:  Sensors (Basel)       Date:  2016-04-02       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.