Improved antibody detection by the use of range expansion and longer filter wavelength in a low ionic strength-protamine sulphate Auto-Analyzer system.

D M Downie, D Voak.   

Abstract

Range expansion, achieved by insertion of a variable resistance between the colorimeter and the recorder together with the use of 550 nm colorimeter filters, has resulted in markedly improved sensitivity for antibody detection, and improved sample identification, in a low ionic strength-protamine sulphate (LISPS) system. Range expansion also permits a lower concentration of red cells to be used, thus economizing on fully typed cells. Glycerol stored frozen cells were found to be only slightly less sensitive than fresh cells in this system.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1002844      PMCID: PMC476253          DOI: 10.1136/jcp.29.11.991

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  12 in total

1.  An evaluation of some factors affecting the detection of blood group antibodies by automated methods.

Authors:  J Kolberg; R Nordhagen
Journal:  Transfusion       Date:  1975 Jul-Aug       Impact factor: 3.157

2.  Automated red cell antibody detection. An improved method.

Authors:  B J Dawes; K L Goldsmith
Journal:  Vox Sang       Date:  1975       Impact factor: 2.144

3.  Quantitative haemagglutination. 6. Relationship of sialic acid content of red cells and aggregation by Polybrene, protamine and poly-L-lysine.

Authors:  T J Greenwalt; E A Steane
Journal:  Br J Haematol       Date:  1973-08       Impact factor: 6.998

4.  A study of the characteristics of certain Rh antibodies preferentially detactable by enzyme technique.

Authors:  F M Casey; B E Dodd; P J Lincoln
Journal:  Vox Sang       Date:  1972-12       Impact factor: 2.144

5.  A papain-bromelin-polybrene four-channel autoanalyzer system for blood group antibody screening. Analysis of 22,912 sera.

Authors:  B Habibi; A Gerbal; C Salmon
Journal:  Vox Sang       Date:  1973-10       Impact factor: 2.144

6.  Automation in the blood transfusion laboratory: I. Antibody dectection and quantitation in the technicon autoanalyzer.

Authors:  B P Moore
Journal:  Can Med Assoc J       Date:  1969-02-22       Impact factor: 8.262

7.  Automated red cell antibody analysis. A parallel study. I. Detection and quantitation.

Authors:  R Perrault; C Högman
Journal:  Vox Sang       Date:  1971-04       Impact factor: 2.144

8.  Range expansion in auto-analyser recorders.

Authors:  J A Owen
Journal:  Clin Chim Acta       Date:  1970-07       Impact factor: 3.786

9.  A range expander unit for AutoAnalyzer recorders.

Authors:  W Annan; G W Fisher
Journal:  Med Lab Technol       Date:  1971-07

10.  The effect of surfactant in the auto-analyser.

Authors:  H H Gunson; P K Phillips; F Stratton
Journal:  Vox Sang       Date:  1972       Impact factor: 2.144

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.