Literature DB >> 10027451

Bioabsorbable self-reinforced poly-L-lactide, metallic, and silicone stents in the management of experimental tracheal stenosis.

A Korpela1, P Aarnio, H Sariola, P Törmälä, A Harjula.   

Abstract

The aim of the present study was to compare, in rabbits, the biocompatibility and suitability of a bioabsorbable spiral stent made of self-reinforced poly-L-lactide (SR-PLLA) in the management of experimental tracheal stenosis with stents made of metal and silicone. Tracheobronchial stenosis, and its management, is still problematic because stenoses are not always amenable to surgical resection and reconstruction, especially concerning anastomotic problems and stenosis after lung transplantation. Stenosis can be handled with stenting, although the ideal stent has yet to be developed; all the stents available have their disadvantages. Because stenting of the airways can be only temporary, stents made of bioabsorbable materials, theoretically, offer benefits. Tracheal stenosis was created in rabbits by the extramucosal resection of cartilaginous arches of the cervical trachea. After a few weeks, the animals were operated on again, and those stenoses that had developed were dilated with a balloon. Stents then were implanted in the area of stenosis to keep the dilated trachea open. All the animals in the group with silicone stents had to be killed because of respiratory difficulties: their stents had a tendency to occlude because of internal encrustation, and they developed a hyperplastic polyp at the ends of the stents. The SR-PLLA and metallic stents were tolerated well, and after follow-up ended the animals were put to death. This experimental study showed that silicone stents had a tendency to occlude and that stents made of metal and of SR-PLLA were well tolerated and can be used in the management of airway stenosis.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10027451     DOI: 10.1378/chest.115.2.490

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  Preclinical evaluation of a pediatric airway stent for tracheobronchomalacia.

Authors:  Abhijit Mondal; Junhyoung Ha; Vickie Y Jo; Fei-Yi Wu; Aditya K Kaza; Pierre E Dupont
Journal:  J Thorac Cardiovasc Surg       Date:  2020-03-15       Impact factor: 5.209

2.  Polymeric implant materials for the reconstruction of tracheal and pharyngeal mucosal defects in head and neck surgery.

Authors:  Dorothee Rickert
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

3.  Biodegradable polydioxanone stents in the treatment of adult patients with tracheal narrowing.

Authors:  Ludek Stehlik; Vladislav Hytych; Jana Letackova; Petr Kubena; Martina Vasakova
Journal:  BMC Pulm Med       Date:  2015-12-21       Impact factor: 3.317

4.  Intervention using a novel biodegradable hollow stent containing polylactic acid-polyprolactone-polyethylene glycol complexes against lacrimal duct obstruction disease.

Authors:  Xinyuan Zhan; Xin Guo; Rong Liu; Weikun Hu; Lei Zhang; Nan Xiang
Journal:  PLoS One       Date:  2017-06-01       Impact factor: 3.240

5.  In-vivo efficacy of biodegradable ultrahigh ductility Mg-Li-Zn alloy tracheal stents for pediatric airway obstruction.

Authors:  Jingyao Wu; Leila J Mady; Abhijit Roy; Ali Mübin Aral; Boeun Lee; Feng Zheng; Toma Catalin; Youngjae Chun; William R Wagner; Ke Yang; Humberto E Trejo Bittar; David Chi; Prashant N Kumta
Journal:  Commun Biol       Date:  2020-12-18

6.  Digital light 3D printing of customized bioresorbable airway stents with elastomeric properties.

Authors:  Nevena Paunović; Yinyin Bao; Fergal Brian Coulter; Kunal Masania; Anna Karoline Geks; Karina Klein; Ahmad Rafsanjani; Jasmin Cadalbert; Peter W Kronen; Nicole Kleger; Agnieszka Karol; Zhi Luo; Fabienne Rüber; Davide Brambilla; Brigitte von Rechenberg; Daniel Franzen; André R Studart; Jean-Christophe Leroux
Journal:  Sci Adv       Date:  2021-02-03       Impact factor: 14.136

  6 in total