Literature DB >> 10025612

Sources of artifact and systematic error in quantitative snapshot of FLASH imaging and methods for their elimination.

C F Williams1, T W Redpath.   

Abstract

Snapshot FLASH preceded by a preparation sequence is used to measure NMR parameters. Some preparation information is lost during snapshot FLASH acquisition as the magnetization evolves towards the steady state. This problem is often addressed by assuming that image intensity is proportional to the central k-space line, which may be sampled immediately after preparation using a centric-reordered scheme. Although some limitations of this assumption have been discussed, they are often ignored in parameter measurement. In this study, magnetization evolution effects in snapshot FLASH were investigated by computer simulation and phantom experiments in the context of T2 measurement. It was found that the standard analysis may lead to significant error in parameter measurement. Some improvement may be obtained using a more sophisticated analysis to take account of magnetization evolution. However, at the expense of a 50% reduction in signal intensity, accurate values may be obtained by a novel method that uses crusher gradients to eliminate evolved magnetization.

Mesh:

Year:  1999        PMID: 10025612     DOI: 10.1002/(sici)1522-2594(199901)41:1<63::aid-mrm10>3.0.co;2-f

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  In vivo T(1rho) mapping in cartilage using 3D magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (3D MAPSS).

Authors:  Xiaojuan Li; Eric T Han; Reed F Busse; Sharmila Majumdar
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

2.  A revisit of the k-space filtering effects of magnetization-prepared 3D FLASH and balanced SSFP acquisitions: Analytical characterization of the point spread functions.

Authors:  Dan Zhu; Qin Qin
Journal:  Magn Reson Imaging       Date:  2022-02-01       Impact factor: 2.546

3.  Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.

Authors:  Donnie Cameron; David M Higgins; Christian Stehning; Marc Kouwenhoven; Mustapha Bouhrara; Michael P Frenneaux; Dana K Dawson; Thomas W Redpath
Journal:  Magn Reson Imaging       Date:  2015-02-07       Impact factor: 3.130

4.  An efficient R dispersion imaging method for human knee cartilage using constant magnetization prepared turbo-FLASH.

Authors:  Yuxi Pang; Riann M Palmieri-Smith; Tristan Maerz
Journal:  NMR Biomed       Date:  2021-03-06       Impact factor: 4.478

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.