Literature DB >> 10023476

Reliability of and comparisons among three variations of the alternating cover test.

B B Rainey1, T L Schroeder, D A Goss, T P Grosvenor.   

Abstract

One of the most commonly used methods for measuring heterophoria is the alternating cover test. Differences in specific procedures and observational criteria used by examiners may result in different measurements of heterophoria on the same patient. This study evaluated the inter-examiner reliability of three different cover test techniques: the estimated cover test, the prism neutralized objective cover test, and the prism neutralized subjective cover test. Two examiners performed each technique on each of 72 subjects. Reliability was assessed using correlational methods and mean difference calculations. Although there were some inter-examiner differences for the different techniques, all of these differences were within previously determined minimum detectable eye movement ranges. Therefore, when used by experienced clinicians, each of these techniques appears to be a reliable method of heterophoria determination, and their results are comparable.

Entities:  

Mesh:

Year:  1998        PMID: 10023476

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  6 in total

Review 1.  Genetic and environmental contributions to strabismus and phoria: evidence from twins.

Authors:  Jeremy B Wilmer; Benjamin T Backus
Journal:  Vision Res       Date:  2009-08-11       Impact factor: 1.886

2.  Characterization of Visual Symptomatology Associated with Refractive, Accommodative, and Binocular Anomalies.

Authors:  Pilar Cacho-Martínez; Mario Cantó-Cerdán; Stela Carbonell-Bonete; Ángel García-Muñoz
Journal:  J Ophthalmol       Date:  2015-08-16       Impact factor: 1.909

3.  Diagnostic validity of clinical signs associated with a large exophoria at near.

Authors:  Pilar Cacho-Martínez; Angel García-Muñoz; María Teresa Ruiz-Cantero
Journal:  J Ophthalmol       Date:  2013-06-17       Impact factor: 1.909

4.  The repeatability and reproducibility of four techniques for measuring horizontal heterophoria: Implications for clinical practice.

Authors:  Nicola S Anstice; Bianca Davidson; Bridget Field; Joyce Mathan; Andrew V Collins; Joanna M Black
Journal:  J Optom       Date:  2020-08-12

5.  Comparison, within-session repeatability and normative data of three phoria tests.

Authors:  Alessio Facchin; Silvio Maffioletti
Journal:  J Optom       Date:  2020-08-04

6.  Measuring the heterophoria: Agreement between two methods in non-presbyopic and presbyopic patients.

Authors:  Mario Cantó-Cerdán; Pilar Cacho-Martínez; Ángel García-Muñoz
Journal:  J Optom       Date:  2017-12-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.